DD32 - Check Vacuum to EGRV Solenoid
- Key "OFF".
- Disconnect the EGR Vacuum (EGRV) solenoid input port vacuum source hose.
- Install a vacuum gauge at the disconnected end of the input port vacuum source hose.
- Key "ON", engine idling.
- Observe the vacuum gauge reading.
- Is vacuum greater than 33 kPa (10 in-Hg)?
Yes -- Remove vacuum gauge. Reconnect vacuum hose. Go to DD33. DD33 - Check EGRV Solenoid Valve Function
No -- Check vacuum hose to the EGRV solenoid. If OK, check vacuum source for the solenoid. Service as necessary. Rerun quick test. Quick Test Appendix (Detailed Testing Instructions)