BB7 Check Circuit 498
- Disconnect valve block connector from wire harness.
- Check for continuity between breakout box pins 2 and 60.
- Is continuity present?
YES -- Replace or service cable harness circuit 498 (PK).
NO -- Reverify DTC 23.
NOTE: If other DTCs are output, service next DTC.