A15 Check FLS No. 2
- Disconnect 2-pin plug from FLS 2, located on hydraulic control unit reservoir.
- Measure resistance between pins 1 and 2 on hydraulic control unit reservoir.
- Is resistance less than 5 ohms?
YES -- Service or replace cable harness.
NO -- Replace hydraulic control unit reservoir.