JC15 - Check C3 at Coil Connector While Cranking Engine
- Connect test lamp between J1 (B+) and J10 (C3C).
- Crank engine.
- Does lamp blink consistently and brightly (one blink per engine revolution)?
YES -- REPLACE coil pack. Input to coil pack is OK, but no high voltage output. REMOVE all test equipment. RECONNECT all components. Clear continuous memory. Clearing Diagnostic Trouble Codes
Rerun quick test. Diagnostic Subroutines (DSR) - Extracting Codes
NO -- REPLACE ICM. C3 open in ICM. REMOVE all test equipment. RECONNECT all components. Clear continuous memory. Clearing Diagnostic Trouble Codes
Rerun quick test. Diagnostic Subroutines (DSR) - Extracting Codes