H54 - Check HO2S Circuit Wiring Harness For Short to Ground
- Key Off.
- Breakout box installed, PCM disconnected.
- HO2S disconnected.
- Measure resistance between the HO2S Signal Test Pin and Test Pins 24, 51, 76, 77 and 103 at the breakout box.
- Is each resistance greater than 10,000 ohms?
YES -- Go to H55. H55 - Check HO2S For Short to Ground
NO -- SERVICE short circuit. REMOVE breakout box. RECONNECT PCM and HO2S. DRIVE 5 miles/55 mph. Rerun quick test. Diagnostic Subroutines (DSR) - Extracting Codes