VPWR4 - Ground at Main Relay
- Key OFF.
- Remove the main relay.
- Measure the resistance of the GND wire between the GND terminal at the main relay harness connector and ground.
- Is the resistance less than 5 ohms?
Yes -- Go to VPWR5. VPWR5 - Battery Voltage at Main Relay
No -- Service the GND wire at the main relay.