FREE REPAIR MANUALS & LABOR GUIDES 1982-2013 Vehicles
Courtesy of Operation CHARM: Car repair manuals for everyone.

A12 - A13



A12 VAPS Harness And Connectors Check
- Disconnect VAPS connector from module.

Voltage Chart:






- Connect DVOM as shown.
- Turn ignition switch to ON.
- Measure voltage at each circuit (circuit 57 to ground).
Are voltage readings near given values?
Yes
Go to A13.
No
SERVICE harness.
REPEAT A12.

A13 VAPS Harness And Connectors Check
- Turn ignition switch to OFF.
- Measure resistance between Circuit 57 ground and all other indicated circuits.






- Connect DVOM as shown.
- Measure resistance of each circuit, by moving positive lead.
Is resistance at given value?

Row Circuit Function Typical Value
Top 200 Diagnostic Open
Top 497 Actuator Open
Top 498 Actuator Open
Top 495 Actuator Open
Bottom 606 Diagnostic Open
Bottom 496 Actuator Open
Bottom - VIP Open

Yes
Go to A2. A1 - A3
No
SERVICE harness.
Go to A2. A1 - A3