Operating Pressure Regulating Valve
LOCATION
- In the shift plate valve housing.
TASK
- To control the main pressure of the hydraulic system.
FUNCTION
- The level of operating pressure (p-A) is controlled at the operating pressure regulating valve according to load (modulator pressure) and gear (K1 or K2 pressure). A minimum level (basic pressure) is adjusted by the spring in the operating pressure regulating valve.
Also Refer To:
- Location Of Hydraulic Components. Automatic Transmission, Location of Hydraulic Components
- Holding Pressure Regulating Valve. Holding Pressure Shift Valve