Transmission Fails After Installation
After Installation, Transmission does not Transmit Power or Fails After a Brief Period of operation
Cause/remedy:
1. Torque converter was not installed in accordance with the specifications. Resultant damage: Primary pump irreparably damaged.
2. Replace primary pump and torque converter, if necessary.