Green and Red Indicators Blink Simultaneously
CELLULAR COMMUNICATION: SAFETY CONNECT SYSTEM: GREEN AND RED INDICATORS BLINK SIMULTANEOUSLY
- GREEN AND RED INDICATORS BLINK SIMULTANEOUSLY
DESCRIPTION
After the engine switch is turned on (IG), the DCM (telematics transceiver) will enter a self-check mode. The manual (SOS) switch red indicator will illuminate for 2 seconds and turn off followed by the manual (SOS) switch green indicator illuminating and remaining on under normal operation.
If both indicators illuminate and begin to blink simultaneously, this indicates that the DCM (telematics transceiver) is in "Shipping Mode." If no DTCs are stored, both the green and red indicators will turn off after blinking. The activation sequence must be performed.
HINT
In shipping mode, the system will attempt to activate shell mode automatically every time the engine switch is turned on (IG).
INSPECTION PROCEDURE
PROCEDURE
1. CHANGE SUBSCRIPTION MODE
(a) Turn the engine switch on (IG).
(b) Push the manual (SOS) switch.
HINT
At this time, a voice prompt plays: "Safety Connect is not initialized. To activate, please press the button again within 5 seconds."
(c) Push the manual (SOS) switch again.
HINT
A beep is emitted when the switch is pressed.
(d) Check that the manual (SOS) switch green indicator illuminates when the telematics service provider sends an End Call command.
(e) Within 3 minutes of the indicator illuminating, check that a voice prompt plays "Activation Complete".
(f) Turn the engine switch off.
NEXT -- Continue to next step.
2. CHECK SUBSCRIPTION MODE
(a) Turn the engine switch on (IG).
(b) Confirm that the manual (SOS) switch red indicator illuminates for 2 seconds and turns off, and the manual (SOS) switch green indicator illuminates and remains on System Description.
NEXT -- END