P2759
A760H AUTOMATIC TRANSMISSION: AUTOMATIC TRANSMISSION SYSTEM (for 4GR-FSE): P2759: Torque Converter Clutch Pressure Control Solenoid Control Circuit Electrical (Shift Solenoid Valve SLU)
P2759 - Torque Converter Clutch Pressure Control Solenoid Control Circuit Electrical (Shift Solenoid Valve SLU)
DESCRIPTION
The amount of current flow to the solenoid is controlled by the (*) duty ratio of the ECM output signal. The higher the duty ratio becomes, the higher the lock-up hydraulic pressure becomes during the lock-up operation.
(*) Duty Ratio
The duty ratio is the ratio of the period of continuity in one cycle. For example, if A is the period of continuity in one cycle, and B is the period of non-continuity, then Duty Ratio = A/(A+B) x 100(%).
Reference (Using an oscilloscope):
Check the waveform between the terminals SLU+ and SLU- of the ECM connector
Standard:
Refer to the illustration.
MONITOR DESCRIPTION
When an open or short in a shift solenoid valve (SLU) circuit is detected, the ECM determines there is a malfunction. The ECM will turn on the MIL and store this DTC.
MONITOR STRATEGY
TYPICAL ENABLING CONDITIONS
TYPICAL MALFUNCTION THRESHOLDS
COMPONENT OPERATING RANGE
WIRING DIAGRAM
INSPECTION PROCEDURE
NOTICE:
Perform the universal trip to clear permanent DTCs Reading and Clearing Diagnostic Trouble Codes.
PROCEDURE
1. INSPECT TRANSMISSION WIRE (SLU)
(a) Disconnect the transmission wire connector from the transmission.
(b) Measure the resistance according to the value(s) in the table below.
Standard resistance:
(c) Measure the resistance according to the value(s) in the table below.
Standard resistance (Check for short):
NG -- INSPECT SHIFT SOLENOID VALVE SLU
OK -- Continue to next step.
2. CHECK HARNESS AND CONNECTOR (TRANSMISSION WIRE - ECM)
(a) Connect the transmission wire connector to the transmission.
(b) Disconnect the ECM connector.
(c) Measure the resistance according to the value(s) in the table below.
Standard resistance:
(d) Measure the resistance according to the value(s) in the table below.
Standard resistance (Check for short):
NG -- REPAIR OR REPLACE HARNESS OR CONNECTOR
OK -- REPLACE ECM
3. INSPECT SHIFT SOLENOID VALVE SLU
(a) Remove the shift solenoid valve SLU.
(b) Measure the resistance according to the value(s) in the table below.
Standard resistance:
(c) Connect the positive (+) lead with a 21 W bulb to terminal 2 and the negative (-) lead to terminal 1 of the solenoid valve connector, then check the movement of the valve.
OK:
The solenoid makes an operating sound.
NG -- REPLACE SHIFT SOLENOID VALVE SLU