Canister Purge Solenoid: Testing and Inspection
2GR-FE EMISSION CONTROL: PURGE VALVE: INSPECTION
1. INSPECT EVAP VSV
(a) Check the VSV for an open circuit.
(1) Measure the resistance.
Standard resistance:
If the resistance is not as specified, replace the VSV assembly.
(b) Check VSV operation.
(1) Check that air does not flow from port E to port F.
(2) Apply battery positive voltage across the terminals.
(3) Check that air flows from port E to port F. If the result is not as specified, replace the purge VSV.
If the result is not as specified, replace the VSV assembly.