Thermostat: Testing and Inspection
2ZR-FXE COOLING: THERMOSTAT: INSPECTION
1. INSPECT WATER INLET WITH THERMOSTAT SUB-ASSEMBLY
(a) Immerse the water inlet with thermostat sub-assembly in water and then gradually heat the water.
(b) Check the valve opening temperature of the water inlet with thermostat sub-assembly.
Valve opening temperature:
80 to 84°C (176 to 183°F)
HINT
If the valve opening temperature is not as specified, replace the water inlet with thermostat sub-assembly.
(c) Check the valve lift.
Text in Illustration
Valve lift:
10 to 14 mm (0.394 to 0.551 in.) at 95°C (203°F)
HINT
If the valve lift is not as specified, replace the water inlet with thermostat sub-assembly.
(d) Check that the valve is fully closed when the water inlet with thermostat sub-assembly is at low temperatures (below 77°C (171°F)).
HINT
If it is not fully closed, replace the water inlet with thermostat sub-assembly.