Radiator Cooling Fan Motor: Testing and Inspection
2ZR-FXE COOLING: COOLING FAN MOTOR: ON-VEHICLE INSPECTION
1. INSPECT COOLING FAN MOTOR
(a) Check that the motor operates smoothly when the battery is connected to the cooling fan motor connector.
Text in Illustration
(b) Clamp the 400 A probe of an ammeter over the (+) wire of the cooling fan motor.
(c) Measure the current while the motor is operating.
Standard Current:
If the result is not as specified, replace the cooling fan motor.
2. INSPECT NO. 2 COOLING FAN MOTOR
(a) Check that the motor operates smoothly when the battery is connected to the No. 2 cooling fan motor connector.
Text in Illustration
(b) Clamp the 400 A probe of an ammeter over the (+) wire of the No. 2 cooling fan motor.
(c) Measure the current while the motor is operating.
Standard Current:
If the result is not as specified, replace the No. 2 cooling fan motor.