AA80E Automatic Transmission
AA80E AUTOMATIC TRANSMISSION: AUTOMATIC TRANSMISSION SYSTEM: P2759: Torque Converter Clutch Pressure Control Solenoid Control Circuit Electrical (Shift Solenoid Valve SLU)
P2759 - Torque Converter Clutch Pressure Control Solenoid Control Circuit Electrical (Shift Solenoid Valve SLU)
DESCRIPTION
The TCM controls the lock-up solenoid using a predetermined duty ratio*, and performs lock-up and flex lock-up control.
HINT
*: The duty ratio is the ratio of the current ON time (A) to the total of the current ON and OFF time (A + B).
Duty Ratio (%) = A / (A + B) x 100
MONITOR DESCRIPTION
When an open or short in a shift solenoid valve SLU circuit is detected, the TCM determines that there is a malfunction. The TCM will illuminate the MIL and store this DTC.
MONITOR STRATEGY
TYPICAL ENABLING CONDITIONS
All
Condition (A)
Condition (B)
Condition (C)
TYPICAL MALFUNCTION THRESHOLDS
When one of the following conditions is met: Condition (A), (B) or (C)
Condition (A) and (B)
Condition (C)
COMPONENT OPERATING RANGE
WIRING DIAGRAM
INSPECTION PROCEDURE
NOTICE:
Perform the universal trip to clear permanent DTCs DTC Check / Clear.
PROCEDURE
1. CHECK HARNESS AND TRANSMISSION WIRE (TRANSMISSION WIRE - TCM, TRANSMISSION WIRE (SHIFT SOLENOID VALVE SLU))
(a) Disconnect the TCM connector.
(b) Measure the resistance of the wire harness side connector.
Standard resistance:
NG -- CHECK HARNESS AND CONNECTOR (TRANSMISSION WIRE - TCM)
OK -- Continue to next step.
2. REPLACE TCM
(a) Replace the TCM Service and Repair.
NEXT -- PERFORM A/T CODE REGISTRATION Registration
3. CHECK HARNESS AND CONNECTOR (TRANSMISSION WIRE - TCM)
(a) Disconnect the transmission wire connector.
(b) Disconnect the TCM connector.
(c) Measure the resistance of the wire harness side connectors.
Standard resistance:
NG -- REPAIR OR REPLACE HARNESS OR CONNECTOR
OK -- Continue to next step.
4. INSPECT SHIFT SOLENOID VALVE SLU
(a) Remove the shift solenoid valve SLU AA80E Automatic Transmission.
(b) Measure the resistance of the shift solenoid valve.
Standard resistance:
(c) Connect the battery's positive (+) lead with a 21 W bulb to terminal 2 and the negative (-) lead to terminal 1 of the solenoid valve connector. Then check that the valve moves and makes an operating sound.
OK:
Valve moves and makes operating sound.
NG -- REPLACE SHIFT SOLENOID VALVE SLU AA80E Automatic Transmission
OK -- REPAIR OR REPLACE TRANSMISSION WIRE