P043E
3UZ-FE ENGINE CONTROL SYSTEM: SFI SYSTEM: P043E: Evaporative Emission System Leak Detection Reference Orifice Low Flow
DTC P043E - Evaporative Emission System Leak Detection Reference Orifice Low Flow
DTC P043F - Evaporative Emission System Reference Orifice High Flow
DTC P2401 - Evaporative Emission Leak Detection Pump Stuck OFF
DTC P2402 - Evaporative Emission Leak Detection Pump Stuck ON
DTC P2419 - Evaporative Emission Pressure Switching Valve Stuck ON
DTC SUMMARY
HINT: The reference orifice is located inside the canister pump module.
DESCRIPTION
The description can be found in the EVAP (Evaporative Emission) System EVAP System.
INSPECTION PROCEDURE
Refer to the EVAP System EVAP System.
MONITOR DESCRIPTION
5 hours* after the ignition switch is turned OFF, the leak detection pump creates negative pressure (vacuum) in the EVAP system. The ECM monitors for leaks and actuator malfunctions based on the EVAP pressure.
HINT: *: If the engine coolant temperature is not below 35°C (95°F) 5 hours after the ignition switch is turned OFF, the monitor check starts 2 hours later. If it is still not below 35°C (95°F) 7 hours after the ignition switch is turned OFF, the monitor check starts 2.5 hours later.
HINT: *: If only a small amount of fuel is in the fuel tank, it takes longer for the EVAP pressure to stabilize.
The leak detection pump creates negative pressure through the reference orifice. When the system is normal, the EVAP pressure is between 724 to 752 mmHg* and saturated within a minute. If not, the ECM interprets this as a malfunction. The ECM will illuminate the MIL and set DTC if this malfunction is detected in consecutive drive cycles.
*: Typical value.
MONITOR STRATEGY
TYPICAL ENABLING CONDITIONS
1. Key-off monitor sequence 1 to 8
1. Atmospheric pressure measurement
2. First reference pressure measurement
3. Vent valve stuck closed check
4. Vacuum introduction
5. Purge VSV stuck closed check
6. Second reference pressure measurement
7. Leak check
8. Atmospheric pressure measurement
TYPICAL MALFUNCTION THRESHOLDS
"Saturated" indicates that the EVAP pressure change is less than 0.286 kPa-g (2.14 mmHg-g) in 60 seconds.
MONITOR RESULT
Refer to CHECKING MONITOR STATUS Mode 6 Data.