FREE REPAIR MANUALS & LABOR GUIDES 1982-2013 Vehicles
Courtesy of Operation CHARM: Car repair manuals for everyone.

P0116








3UZ-FE ENGINE CONTROL SYSTEM: SFI SYSTEM: P0116: Engine Coolant Temperature Circuit Range / Performance Problem

DTC P0116 - Engine Coolant Temperature Circuit Range / Performance Problem

DESCRIPTION





A thermistor is built into the Engine Coolant Temperature (ECT) sensor and changes the resistance value according to the engine coolant temperature.
The structure of the sensor and connection to the ECM is the same as the Intake Air Temperature (IAT) sensor.
HINT: If the ECM detects the DTC P0115, P0117 or P0118, it operates the fail-safe function in which the ECT is assumed to be 80°C (176°F).






MONITOR DESCRIPTION

ECT sensor cold start monitor

When a cold engine start is performed and then the engine is warmed up, if the ECT sensor value does not change, it is determined that a malfunction has occurred. If this is detected in 2 consecutive driving cycles, the MIL is illuminated and a DTC is set.

ECT sensor soak monitor

If the ECT sensor value does not change after the warmed up engine is stopped and then the next cold engine start is performed, it is determined that a malfunction has occurred. If this is detected in 2 consecutive driving cycles, the MIL is illuminated and a DTC is set.

MONITOR STRATEGY





TYPICAL ENABLING CONDITIONS





Cold start monitor:





Soak monitor:





TYPICAL MALFUNCTION THRESHOLDS

Cold start monitor:





Soak monitor:





COMPONENT OPERATING RANGE





WIRING DIAGRAM





INSPECTION PROCEDURE
HINT:
- If DTC P0115, P0116, P0117, P0118 and P0125 are output simultaneously, ECT sensor circuit may be open or shorted. Perform the troubleshooting of DTC P0115, P0117 or P0118 first.
- Read freeze frame data using the Techstream. Freeze frame data records the engine conditions when a malfunction is detected. When troubleshooting, freeze frame data can help determine if the vehicle was running or stopped, if the engine was warmed up or not, if the air-fuel ratio was lean or rich, and other data from the time the malfunction occurred.

PROCEDURE

1. CHECK OTHER DTC OUTPUT (IN ADDITION TO DTC P0116)
Result:






B -- GO TO RELEVANT DTC CHART
A -- Continue to next step.
2. INSPECT THERMOSTAT
(a) Remove the thermostat Testing and Inspection.
(b) Check the valve opening temperature of the thermostat.
OK:
Temperature value is 80 to 84°C (176 to 183°F)
HINT: In addition to the above check, confirm that the valve is completely closed when the temperature is below the standard.

NG -- REPLACE THERMOSTAT
OK -- REPLACE ENGINE COOLANT TEMPERATURE SENSOR