FREE REPAIR MANUALS & LABOR GUIDES 1982-2013 Vehicles
Courtesy of Operation CHARM: Car repair manuals for everyone.

P0441

DTC P0441 Evaporative Emission Control System Incorrect Purge Flow

CIRCUIT DESCRIPTION







DTC Detecting Condition:




The vapor pressure sensor, canister closed valve (CCV), pressure switching valve are used to detect abnormalities in the evaporative emission control system.

The ECM decides whether there is an abnormality in the evaporative emission control system based on the vapor pressure sensor signal.

DTCs P0441 and P0446 are recorded by the ECM when evaporative emissions leak from the components within the dotted line in Fig. 1, or when there is a malfunction in either the EVAP VSV, the pressure switching valve, or in the vapor pressure sensor itself.






HINT: Typical DTC output of each trouble part

MONITOR DESCRIPTION

Monitor Strategy:




Typical Enabling Conditions:




Typical Malfunction Thresholds:






P0441
The ECM checks for a stuck closed malfunction in the EVAP VSV by commanding it to open with the CCV closed. If a high negative pressure does not develop in the fuel tank, the ECM determines that the VSV for EVAP remains closed. The ECM turns on the MIL and a DTC is set.

The ECM checks for EVAP VSV "stuck open" fault by commanding both valves (EVAP VSV and CCV) to close at a time when the fuel tank is at atmospheric pressure. If the fuel tank develops a high negative pressure at this early stage of the test, the ECM determines that the EVAP VSV is stuck OPEN.

The ECM will turn on the MIL and a DTC is set.

MONITOR RESULT (MODE 06 DATA)

Monitor Result (Mode 06 Data):




Refer to "Monitors, Trips and/or Drive Cycle" for detailed information.

The test value and test limit information are described as shown in the table. Check the monitor result and test values after performing the monitor drive pattern.
- TID (Test Identification Data) is assigned to each emissions-related component.
- TID (Test Limit Type):
If TLT is 0, the component is malfunctioning when the test value is higher than the test limit.
If TLT is 1, the component is malfunctioning when the test value is lower than the test limit.

- CID (Component Identification Data) is assigned to each test value.
- Unit Conversion is used to calculate the test value indicated on generic OBD II scan tools.

Wiring Diagram:






INSPECTION PROCEDURE

HINT:
- If DTC P0441 (Purge Flow), P0446 (CCV) or pressure switching valve or P0451 (Evaporative Pressure Sensor) is output with DTC P0442, P0455 or P0456, first troubleshoot DTC P0441, P0446 or P0451. If no malfunction is detected, troubleshoot DTC P0442, P0455 or P0456 next.
- Read freeze frame data using the hand-held tester or the OBD II scan tool. Freeze frame data records the engine conditions when a malfunction is detected. When troubleshooting, freeze frame data can help determine if the vehicle was running or stopped, if the engine was warmed up or not, if the air-fuel ratio was lean or rich, as well as other data from the time when a malfunction occurred.
- When the ENGINE RUN TIME in the freeze frame data is less than 200 seconds, carefully check the vapor pressure sensor.

Step 1 - 3:




Step 4 - 5:




Step 6 - 8:




Step 9 - 10:




Step 11 - 13:




Step 14 - 16:




Step 17 - 19:




Step 20 - 22:




Step 23 - 24:




Hand-held tester

Step 1 - 4:




Step 5 - 7:




Step 8 - 10:




Step 11 - 12:




Step 13 - 15:




Step 16 - 18:




Step 19 - 21:




Step 22 - 24:




OBD II scan tool (excluding hand-held tester