FREE REPAIR MANUALS & LABOR GUIDES 1982-2013 Vehicles
Courtesy of Operation CHARM: Car repair manuals for everyone.

P1238




P1238, P2119 ELECTRIC THROTTLE CONTROL ACTUATOR

DTC Logic


DTC DETECTION LOGIC







DTC CONFIRMATION PROCEDURE


1. PRECONDITIONING

If DTC Confirmation Procedure has been previously conducted, always perform the following procedure before conducting the next test.
1.Turn ignition switch OFF and wait at least 10 seconds.
2.Turn ignition switch ON.
3.Turn ignition switch OFF and wait at least 10 seconds.
- GO TO 2.

2. PERFORM DTC CONFIRMATION PROCEDURE FOR MALFUNCTION A AND B

1.Turn ignition switch ON and wait at least 1 second.
2.Shift selector lever to D position and wait at least 3 seconds.
3.Shift selector lever to P position.
4.Turn ignition switch OFF and wait at least 10 seconds.
5.Turn ignition switch ON and wait at least 1 second.
6.Shift selector lever to D position and wait at least 3 seconds.
7.Shift selector lever to P position.
8.Turn ignition switch OFF, wait at least 10 seconds, and then turn ON.
9.Check DTC.
Is DTC detected?
YES- Go to .
NO- GO TO 3.

3. PERFORM DTC CONFIRMATION PROCEDURE FOR MALFUNCTION C

1.Turn ignition switch ON and wait at least 1 second.
2.Shift selector lever to D position and wait at least 3 seconds.
3.Shift selector lever to P position.
4.Start engine and let it idle for 3 seconds.
5.Check DTC.
Is DTC detected?
YES- Go to .
NO- INSPECTION END


Diagnosis Procedure


1. CHECK ELECTRIC THROTTLE CONTROL ACTUATOR VISUALLY

1.Turn ignition switch OFF.
2.Remove the intake air duct.





3.Check if foreign matter is caught between the throttle valve (1)
and the housing.
Is the inspection result normal?
YES- GO TO 2.
NO- Remove the foreign matter and clean the electric throttle control actuator inside.

2. REPLACE ELECTRIC THROTTLE CONTROL ACTUATOR

1.Replace malfunctioning electric throttle control actuator.
2.Go to .
- INSPECTION END


Special Repair Requirement


1. PERFORM THROTTLE VALVE CLOSED POSITION LEARNING

Work Procedure
- GO TO 2.

2. PERFORM IDLE AIR VOLUME LEARNING

Work Procedure
- END