Diagnosis Procedure
AIR MIX DOOR MOTOR
WITHOUT LEFT AND RIGHT VENTILATION TEMPERATURE SEPARATELY CONTROL SYSTEM : Diagnosis Procedure
1. PERFORM SELF-DIAGNOSIS
Perform self-diagnosis function. Without Plasmacluster System.
Is the inspection result normal?
YES- GO TO 5.
NO- GO TO 2.
2. CHECK POWER SUPPLY FOR AIR MIX DOOR MOTOR
Check voltage between air mix door motor harness connector and ground.
Is the inspection result normal?
YES- GO TO 3.
NO- Repair harness or connector.
3. CHECK SIGNAL FOR AIR MIX DOOR MOTOR
Confirm A/C LAN signal between air mix door motor harness connector and ground using an oscilloscope.
Is the inspection result normal?
YES- GO TO 4.
NO- Repair harness or connector.
4. CHECK AIR MIX DOOR MOTOR GROUND CIRCUIT
1.Turn ignition switch OFF.
2.Disconnect air mix door motor connector.
3.Check continuity between air mix door motor harness connector and ground.
Is the inspection result normal?
YES- Replace air mix door motor.
NO- Repair harness or connector.
5. CHECK INSTALLATION OF AIR MIX DOOR MOTOR
Check air mix door motor is properly installed. Door Motor.
Is it installed normally?
YES- INSPECTION END