Diagnosis Procedure
VDC OFF INDICATOR LAMP
Description
VDC OFF INDICATOR LAMP
Diagnosis Procedure
1.CHECK VDC OFF SWITCH
Check that the VDC OFF indicator lamp in the combination meter turns ON/OFF correctly when operating the
VDC OFF switch.
Is the inspection result normal?
YES - GO TO 2.
NO - Check VDC OFF switch. Diagnosis Procedure.
2.CHECK SELF-DIAGNOSIS
Perform self-diagnosis for "ABS" with CONSULT-III.
Is the inspection result normal?
YES - GO TO 3.
NO - Check items displayed by self-diagnosis.
3.CHECK COMBINATION METER
Check if the indication and operation of combination meter are normal. CONSULT-III Function.
Is the inspection result normal?
YES - Replace ABS actuator and electric unit (control unit).
NO - Repair or replace combination meter.