Flipper Door Motor
FLIPPER DOOR MOTOR
Description
Flipper door (LH/RH) is installed on trunk lid back side. Each flipper door integrates flipper door motor and flipper door limit switch. Up and down operations are performed by flipper door motor. Up and down positions of flipper door are detected by flipper door limit switch.
FLIPPER DOOR MOTOR
Diagnosis Procedure
1.CHECK FLIPPER DOOR MOTOR CIRCUIT-1
1. Turn ignition switch OFF.
2. Disconnect retractable hard top control unit connector and hydraulic unit connector.
3. Check the continuity between retractable hard top control unit harness connector and hydraulic unit harness connector.
4. Check harness for short to ground.
Is the inspection result normal?
YES - GO TO 2.
NO - Repair or replace harness.
2.CHECK FLIPPER DOOR MOTOR CIRCUIT-2
1. Disconnect flipper door (LH/RH) connector.
2. Check the continuity between hydraulic unit harness connector and flipper door (LH/RH) connector.
3. Check harness for short to ground.
Is the inspection result normal?
YES - GO TO 3.
NO - Repair or replace harness.
3.CHECK FLIPPER DOOR POWER SUPPLY
1. Turn ignition switch OFF.
2. Connect retractable hard top control unit connector and hydraulic unit connector.
3. Turn ignition switch ON.
4. Check the voltage between flipper door harness connector and ground with CONSULT-III.
Is the inspection result normal?
YES - Replace flipper door (malfunctioning part). Refer to Removal and Installation.
NO - GO TO 4.
4.CHECK RETRACTABLE HARD TOP CONTROL UNIT OUTPUT
1. Turn ignition switch OFF.
2. Connect flipper door (LH/RH) connector.
3. Turn ignition switch ON.
4. Check "FLPD OUT(UP)" and "FLPD OUT(DWN)" in retractable hard top control unit "Data Monitor" mode using CONSULT-III.
Is the inspection result normal?
YES - Replace hydraulic unit. Refer to Removal and Installation.
NO - Replace retractable hard top control unit. Refer to Service and Repair.