P0710
DescriptionThe A/T fluid temperature sensor detects the A/T fluid temperature and sends a signal to the TCM.
CONSULT-II REFERENCE VALUE IN DATA MONITOR MODE
TCM TERMINALS AND REFERENCE VALUE
Remarks: Specification data are reference values.
ON BOARD DIAGNOSIS LOGIC
DIAGNOSTIC TROUBLE CODE (DTC) CONFIRMATION PROCEDURE
CAUTION: Always drive vehicle at a safe speed.
NOTE: If "DIAGNOSTIC TROUBLE CODE CONFIRMATION PROCEDURE" has been previously conducted, always turn ignition switch "OFF" and wait at least 5 seconds before conducting the next test.
After the repair, perform the procedure to confirm the malfunction is eliminated.
With CONSULT-II
1) Turn ignition switch "ON" and select "DATA MONITOR" mode for "ENGINE" with CONSULT-II.
2) Start engine and maintain the conditions for at least 10 minutes (Total). (It is not necessary to maintain continuously.)
CMPS-RPM (REF): 450 rpm or more
VHCL SPEED SE: 10 km/h (6 MPH) or more
THRTL POS SEN: More than 1.2 V
Selector lever: D position (OD "ON")
With GST
Follow the procedure "With CONSULT-II".
Wiring Diagram - AT - FTS
Diagnostic Procedure
Part 1 of 4
Part 2 of 4
Part 3 of 4
Part 4 of 4
Component Inspection
A/T FLUID TEMPERATURE SENSOR
- For removal, refer to Valve Body; Service and Repair.
- Check resistance between two terminals while changing temperature as shown.