EPS Indicator Does Not Go Off, And No DTCs Are Stored
EPS Symptom Troubleshooting - EPS indicator does not go off, and no DTCs are stored
EPS indicator does not go off, and no DTCs are stored
NOTE: Check for gauge DTCs with the HDS. If gauge DTCs are stored, troubleshoot those DTCs first.
1. Turn the ignition switch to LOCK (0).
2. Check the No. 4 (7.5 A) fuse in the under-dash fuse/relay box.
Is the fuse blown?
YES -
Go to step 3.
NO -
Reinstall the checked fuse, then go to step 7.
3. Disconnect EPS control unit connector D (28P).
4. Check for continuity between EPS control unit connector D (28P) terminal No. 16 and body ground.
Is there continuity?
YES -
Repair a short to body ground in the wire between the EPS control unit and the No. 4 (7.5 A) fuse in the under-dash fuse/relay box.�
NO -
Install a new No. 4 (7.5 A) fuse in the under-dash fuse/relay box, then go to step 5.
5. Reconnect EPS control unit connector D (28P).
6. Turn the ignition switch to ON (II), and watch the EPS indicator.
Does the EPS indicator come on, then go off?
YES -
The system is OK at this time.�
NO -
Replace the EPS control unit Service and Repair.�
7. Disconnect EPS control unit connector D (28P).
8. Turn the ignition switch to ON (II).
9. Measure the voltage between EPS control unit connector D (28P) terminal No. 16 and body ground.
Is there battery voltage?
YES -
Go to step 10.
NO -
Repair an open in the wire between the EPS control unit and under-dash fuse/relay box.�
10. Turn the ignition switch to LOCK (0).
11. Disconnect EPS control unit connector A (2P).
12. Check for continuity between EPS control unit connector A (2P) terminal No. 1 and body ground.
Is there continuity?
YES -
Go to step 13.
NO -
Repair an open in the wire between the EPS control unit and body ground (G402).�
13. Disconnect the gauge control module (tach) 36P connector.
14. Check for continuity between EPS control unit connector D (28P) terminal No. 1 and gauge control module (tach) 36P connector terminal No. 1.
Is there continuity?
YES -
Go to step 15.
NO -
Repair an open in the wire between the EPS control unit and the gauge control module (tach).�
15. Check for continuity between EPS control unit connector D (28P) terminal No. 15 and gauge control module (tach) 36P connector terminal No. 19.
Is there continuity?
YES -
Check for loose terminals in the EPS control unit connectors, and repair if necessary. If no poor connections are found, replace the EPS control unit Service and Repair.�
NO -
Repair an open in the wire between the EPS control unit and the gauge control module (tach).�