Pinpoint Test D: A Single Power Window is Inoperative - RH Front, SHO, Limited
Glass, Frames and Mechanisms
Pinpoint Test D: A Single Power Window is Inoperative - RH Front, SHO, Limited
Refer to Wiring Diagram Set 100, Power Windows for schematic and connector information. Diagrams By Number
NOTE: A new power window motor will not operate in one-touch up mode until initialized. Refer to Window Motor Initialization .
Normal Operation
Under normal operation, the RH front power window motor receives high current power at all times through circuit SBP04 (GN/RD). Ground is provided to the RH front power window motor through circuit GD145 (BK/BU). The RH front power window motor receives low current power from the accessory delay relay through circuit CBB38 (GY/BU). When the LH front window control switch is in the UNLOCK position, voltage is supplied to the RH front window control switch through circuit CPW14 (VT/WH). When the RH front or LH front window control switch is operated in the UP position, the RH front window motor receives a voltage signal through circuit CPW13 (BN/YE). When the RH front or LH front window control switch is operated in the DOWN position, the RH front window motor receives a voltage signal through circuit CPW12 (GN/OG).
This pinpoint test is intended to diagnose the following:
- Fuse
- Wiring, terminals or connectors
- LH front window control switch
- RH front window control switch
- RH front window regulator motor
PINPOINT TEST D : A SINGLE POWER WINDOW IS INOPERATIVE - RH FRONT, SHO, LIMITED
NOTICE: Use the correct probe adapter(s) from the Flex Probe Kit when making measurements. Failure to use the correct probe adapter(s) may damage the connector.
D1 CHECK THE RH FRONT WINDOW OPERATION FROM THE LH FRONT WINDOW CONTROL SWITCH
- Ignition ON.
- Operate the RH front window from the LH front window control switch.
Does the RH front window operate from the LH front window control switch?
Yes
GO to D8.
No
GO to D2.
D2 CHECK THE POWER TO THE WINDOW MOTOR
- Ignition OFF.
- Disconnect: RH Front Window Motor C646.
- Measure the voltage between RH front window motor C646-1, circuit SBP04 (GN/RD), harness side and ground.
Is the voltage greater than 10 volts?
Yes
GO to D3.
No
VERIFY Smart Junction Box (SJB) fuse 4 (30A) is OK. If OK, REPAIR the circuit. DE-INITIALIZE, then INITIALIZE the RH front window motor. REFER to Window Motor Initialization . TEST the system for normal operation.
If not OK, Refer to the Wiring Diagrams to identify the possible causes of the circuit short. REPAIR the circuit. DE-INITIALIZE, then INITIALIZE the RH front window motor. REFER to Window Motor Initialization . TEST the system for normal operation. Diagrams By Number
D3 CHECK THE RH FRONT WINDOW MOTOR DELAYED ACCESSORY FEED
- Ignition ON.
- Measure the voltage between RH front window motor C646-3, circuit CBB38 (GY/BU), harness side and ground.
Is the voltage greater than 10 volts?
Yes
GO to D4.
No
REPAIR the circuit. DE-INITIALIZE, then INITIALIZE the RH front window motor. REFER to Window Motor Initialization . TEST the system for normal operation.
D4 CHECK THE RH FRONT WINDOW MOTOR GROUND
- Ignition OFF.
- Measure the resistance between RH front window motor C646-2, circuit GD145 (BK/BU), harness side and ground.
Is the resistance less than 5 ohms?
Yes
GO to D5.
No
REPAIR the circuit. DE-INITIALIZE, then INITIALIZE the RH front window motor. REFER to Window Motor Initialization . TEST the system for normal operation.
D5 CHECK CIRCUIT CPW12 (GN/OG) FOR AN OPEN
- Disconnect: LH Front Window Control Switch C504.
- Measure the resistance between RH front window motor C646-5, circuit CPW12 (GN/OG), harness side and LH front window control switch C504-10, circuit CPW12 (GN/OG), harness side.
Is the resistance less than 5 ohms?
Yes
GO to D6.
No
REPAIR the circuit. DE-INITIALIZE, then INITIALIZE the RH front window motor. REFER to Window Motor Initialization . TEST the system for normal operation.
D6 CHECK CIRCUIT CPW13 (BN/YE) FOR AN OPEN
- Measure the resistance between RH front window motor C646-4, circuit CPW13 (BN/YE), harness side and LH front window control switch C504-11, circuit CPW13 (BN/YE), harness side.
Is the resistance less than 5 ohms?
Yes
GO to D7.
No
REPAIR the circuit. DE-INITIALIZE, then INITIALIZE the RH front window motor. REFER to Window Motor Initialization . TEST the system for normal operation.
D7 CHECK THE LH FRONT WINDOW CONTROL SWITCH
- Carry out the LH front window control switch component test.
Did the LH front window control switch pass the component test?
Yes
INSTALL a new RH front window regulator motor. REFER to Window Regulator Motor - Front Door . INITIALIZE the RH front window motor. REFER to Window Motor Initialization . TEST the system for normal operation.
No
INSTALL a new LH front window control switch. REFER to Window Control Switch . INITIALIZE the LH front window motor. REFER to Window Motor Initialization . TEST the system for normal operation.
D8 CHECK THE POWER TO THE RH FRONT WINDOW CONTROL SWITCH
NOTE: Make sure the LH window control switch is in the UNLOCK position.
- Ignition OFF.
- Disconnect: RH Front Window Control Switch C648.
- Ignition ON.
- Measure the voltage between RH front window control switch C648-1, circuit CPW14 (VT/WH), harness side and ground.
Is the voltage greater than 10 volts?
Yes
GO to D9.
No
REPAIR the circuit. DE-INITIALIZE, then INITIALIZE the RH front window motor. REFER to Window Motor Initialization . TEST the system for normal operation.
D9 CHECK CIRCUIT CPW12 (GN/OG) FOR AN OPEN
- Ignition OFF.
- Measure the resistance between RH front window motor C646-5, circuit CPW12 (GN/OG), harness side and RH front window control switch C648-3, circuit CPW12 (GN/OG), harness side.
Is the resistance less than 5 ohms?
Yes
GO to D10.
No
REPAIR the circuit. DE-INITIALIZE, then INITIALIZE the RH front window motor. REFER to Window Motor Initialization . TEST the system for normal operation.
D10 CHECK CIRCUIT CPW13 (BN/YE) FOR AN OPEN
- Measure the resistance between RH front window motor C646-4, circuit CPW13 (BN/YE), harness side and RH front window control switch C648-2, circuit CPW13 (BN/YE), harness side.
Is the resistance less than 5 ohms?
Yes
GO to D11.
No
REPAIR the circuit. DE-INITIALIZE, then INITIALIZE the RH front window motor. REFER to Window Motor Initialization . TEST the system for normal operation.
D11 CHECK THE RH FRONT WINDOW CONTROL SWITCH
- Carry out the RH front window control switch component test.
Did the window control switch pass the component test?
Yes
INSTALL a new RH front window regulator motor. REFER to Window Regulator Motor - Front Door . INITIALIZE the RH front window motor. REFER to Window Motor Initialization . TEST the system for normal operation.
No
INSTALL a new RH front window control switch. REFER to Window Control Switch . INITIALIZE the RH front window motor. REFER to Window Motor Initialization . TEST the system for normal operation.