Programming and Relearning
Roof Opening Panel Motor Initialization
NOTE: A new roof opening panel motor will only vent and must be initialized.
NOTE: The roof opening panel motor must be initialized when repairs are carried out on any part of the roof opening panel system, including: whenever the roof opening panel motor has been removed from the roof opening panel system, the roof opening panel glass has been removed from the roof opening panel system, the roof opening panel assembly has been removed from the vehicle, a new roof opening panel motor has been installed, a new roof opening panel glass has been installed or a new roof opening panel assembly has been installed.
1. Turn the ignition to the RUN position. For an existing roof opening panel motor, skip to Step 3.
2. For a new roof opening panel motor, push and hold the tilt switch for 2 seconds after the roof opening panel glass moves to the full VENT position and the motor stalls.
3. For an existing roof opening panel motor, push and hold the tilt switch until the roof opening panel glass moves to full VENT. Then push and hold the tilt switch until the following actions occur:
1. The roof opening panel glass motor stalls into a hard stop after approximately 3 seconds.
2. Then, after motor stalls, continue holding for an additional 5 seconds.
4. Release the tilt switch and verify successful initialization by carrying out one-touch open, one-touch close and one-touch vent operations.