Test A: The Red Brake Warning Indicator Is Always On
Pinpoint Test A: The Red Brake Warning Indicator Is Always OnNormal Operation
Voltage is supplied by the smart junction box (SJB) to the park brake switch circuit 511 (LG). Ground is provided through circuit 57 (BK). Voltage is supplied by the SJB to the park brake fluid level switch circuit 547 (LG/YE). Ground is provided through circuit 57 (BK).
Possible Causes
^ Parking brake switch
^ Parking brake fluid level switch
^ Instrument cluster
^ Circuitry
^ Smart junction box (SJB)