Test E: The Doors Do Not Lock/Unlock Using the Remote Keyless Entry (RKE) Keypad
PINPOINT TEST E: THE DOORS DO NOT LOCK/UNLOCK USING THE REMOTE KEYLESS ENTRY (RKE) KEYPADE1-E5:
E6-E8:
E8-E9:
Normal Operation
When a button is pressed on the RKE keypad a signal is sent to the smart junction box (SJB) through circuits 78 (LB/YE), 122 (YE) and 123 (RD) to activate the function requested.
Possible Causes
- circuit 57 open
- circuit 78 (LB/YE) open or short to ground
- circuit 122 (YE) open or short to ground
- circuit 123 (RD) open or short to ground
- RKE keypad
- SJB