Diagnostic Routine H
Diagnostic Routine H
Diagnostic Overview
Unable To Pair Bluetooth Device
Normal Operation and Fault Conditions
REFER to Bluetooth Mode .
Pinpoint Test
1. CHECK THE BLUETOOTH CONNECTION
1. NOTE: Carrying out a Master Reset returns all preference settings to the factory defaults, erases all the phone book and call histories and deletes any devices paired with the SYNC(R) system.
Connect: 105-00120.
2. Using the 105-00120 , connect to the SYNC(R) system using Bluetooth. Follow the tool instructions.
3. Using a scan tool, view the APIM (Accessory Protocol Interface Module) PIDs (Parameter Identifications).
4. Monitor the Bluetooth device paired PID (BT_PAIR) and the Bluetooth device connected PID (BT_CONN).
Do the PIDs (Parameter Identifications) both read "Yes"?
2. CHECK FOR CORRECT APIM (Accessory Protocol Interface Module) OPERATION
1. Disconnect and inspect the APIM (Accessory Protocol Interface Module) connector.
2. Repair:
- corrosion (install new connector or terminals- clean module pins)
- damaged pins - install new terminals/pins
- pushed-out pins - install new pins as necessary
3. Reconnect the APIM (Accessory Protocol Interface Module) connector. Make sure it seats and latches correctly.
4. Wait 2 minutes for the APIM (Accessory Protocol Interface Module) to re-initialize.
5. Operate the system and determine if the concern is still present.
Is the concern still present?