Alternator: Service and Repair
Generator - 4.0L SOHC
Removal and Installation
NOTE: The radial arm adapter is a serviceable item. Do not replace the generator if the radial arm adapter is the only concern.
1. Disconnect the battery. For additional information, refer to Battery.
2. Rotate the Front End Accessory Drive (FEAD) belt tensioner counterclockwise and position the FEAD belt aside.
3. Position the protective cover aside and remove and discard the generator B+ terminal nut.
- To install, tighten to 17 Nm (150 lb-in).
4. Disconnect the generator B+ terminal and the 2 electrical connectors.
5. Remove the 3 bolts and the generator.
- To install, tighten to 47 Nm (35 lb-ft).
6. If necessary, remove the nut and the generator pulley.
- To install, tighten to 109 Nm (80 lb-ft).
7. To install, reverse the removal procedure.
- Install a new generator B+ terminal nut.