Battery Power to Module Disconnected
Test 1 - 2:
Test 3 - 9:
SYMPTOM
BATTERY POWER TO MODULE DISCONNECTED
WHEN MONITORED
Constantly monitored.
SET CONDITION
The input voltage to the Body Control Module drops below 5 volts.
POSSIBLE CAUSES
- BCM defect - fused ignition switch out
- BCM Fused ignition switch out circuit shorted to ground - BCM
- BCM CCD BCM ground circuit open
- BCM BCM defect
- BCM Fuse # 11 defective
- BCM No response ignition switch output voltage
- BCM No response fused B+ volt low
- BCM No response fused ignition output voltage