CCD Short to Battery
Test 163 - 167:
Test 168 - 172:
Test 173 - 178:
Test 179:
SYMPTOM
* CCD SHORT TO BATTERY
POSSIBLE CAUSES
- Defective DRB/Short to battery
- CCD CAB Circuit short to battery
- CCD bus (+) short to 8 V supply circuit
- CCD bus (-) short to 8 V supply circuit
- CCD IC GND CKT red open
- CCD bus (+) CKT-short to voltage
- CCD bus (-) CKT-short to voltage
- - CCD IC GND CKT blue open
- CCD B+ short to voltage > 0.5
- CCD bus (-) short to voltage
- CCD BCM short to battery default
- CCD ACM short to battery
- CCD SKIM short to battery
- CCD TCM short to battery
- Defective BCM-engine connector
- IC Defect GND CKT open
- PCM defect bus (-) short to 8 V