P0134
Tests 167 - 171:
Tests 172 - 174:
SYMPTOM
P-0134 O2 SENSOR 1/1 STAYS AT CENTER
WHEN MONITORED
With engine running for more than 2 minutes and engine temperature > 170 degrees F
SET CONDITION
The upstream oxygen sensor signal voltage is between 0.35 and 0.55 volt for 1.5 minutes.
POSSIBLE CAUSES
- O2 sensor 1/1 ground circuit open
- O2 sensor 1/1 signal circuit open
- O2 sensor 1/1 wiring harness intermittent defect
- O2 sensor 1/1 wiring harness observable defect
- O2 sensor 1/1 connector observable defect
- O2 sensor defective
- PCM defective