Glove Compartment: Adjustments
ADJUSTING THE GLOVE COMPARTMENT
NOTE: Close attention must be paid to the uniform transition and gap width of the glove compartment lid in relation to the instrument panel.
1. Screw in the stop buffer on the closing surface (1).
2. Loosen the screw (4) to the striker latch. Adjust the gap width and transition at the top.
3. Loosen the hinge screws (2) and adjust the gap width and transition at the bottom and sides.
4. Unscrew both stop buffers until the glove compartment lid makes contact and can still be closed easily.
5. Check for easy motion and proper function.