Air Cleaner Outlet Duct Replacement
Air Cleaner Outlet Duct Replacement
Removal Procedure
1. Remove the air cleaner assembly. Refer to Air Cleaner Assembly Replacement (Service and Repair).
2. Loosen the air intake duct to turbo clamp.
3. Remove the intake air duct.
Installation Procedure
1. Install the intake air duct.
Caution: Refer to Fastener Caution (Fastener Caution).
2. Tighten the intake air duct to turbo clamp to 8 Nm (71 lb in).
3. Install the air cleaner assembly. Refer to Air Cleaner Assembly Replacement (Service and Repair).