Refrigerant Pressure Sensor / Switch: Service and Repair
Air Conditioning (A/C) Refrigerant Pressure Sensor Replacement
Removal Procedure
Caution: Refer to Battery Disconnect Caution Battery Disconnect Caution.
1. Disconnect the negative battery cable.
2. Release the connector lock and pull the transducer wire connector out.
3. Remove the transducer with a wrench.
4. Discard the O-ring seal.
Installation Procedure
1. Install the new O-ring seal on the transducer.
Notice: Refer to Fastener Notice Fastener Notice.
2. Install the pressure transducer.
Tighten the pressure transducer to 7 Nm (62 lb in).
3. Connect the wire connector.
4. Connect the negative battery cable.