Air Conditioning System Seal Replacement
Air Conditioning System Seal Replacement
Removal Procedure
1. Disassemble the A/C refrigerant components. Refer to the appropriate repair procedure.
Note:
Cap or tape the open A/C refrigerant components immediately to prevent system contamination.
2. Cap or tape the A/C refrigerant components.
3. Remove the sealing washer (1) from the A/C refrigerant component.
4. Inspect the seal washer for signs of damage to help determine the root cause of the failure.
5. Inspect the A/C refrigerant components for damage or burrs. Repair if necessary.
Note:
DO NOT reuse sealing washer.
6. DISCARD the sealing washer.
Installation Procedure
Note:
Flat washer type seals do not require lubrication.
1. Inspect the new sealing washer for any signs of cracks, cuts, or damage.
Do not use a damaged sealing washer.
2. Remove the cap or tape from the A/C refrigerant components.
3. Using a lint-free clean, dry cloth, clean the sealing surfaces of the A/C refrigerant components.
4. Carefully install the NEW sealing washer (1) onto the A/C refrigerant component.
The sealing washer (1) must completely bottom against the surface of the fitting.
Note:
After tightening the A/C components, there should be a slight sealing gap of approximately 1.2 mm (3/64 in) between the A/C line and the A/C component.
5. Assemble the remaining A/C refrigerant components. Refer to the appropriate repair procedure.