Defect Code 27 - 44
Defect Code 27 - 44:*D* 900 Defect code memory: One or more defect codes between 27 and 44 are stored:
Explanation: The potentiometer voltage (0.1 V to 4.5 V) drops below or exceeds the permissible voltage range.
Possible cause: The wire has a short or a break, potentiometer defective.
Troubleshooting:
1. Check wires from the control unit to potentiometer, repair if necessary.