Evaporator, Cleaning With Ultrasound A/C Cleaner






Evaporator, Cleaning with Ultrasound A/C Cleaner

Tools required

Ultrasound A/C Cleaner (VAS 6189).

Cleaning Fluid (VAS 6189/1)

There are many different methods for cleaning the evaporator offered on the market. Currently Audi offers the (VAS 6189) which has been approved and released for cleaning the evaporator.

Odors from the air conditioning system can be caused by various things, only a portion of these orders come from the evaporator and can be corrected by cleaning it with, for example, the (VAS 6189).

Causes of Odor, refer to => [ Causes of Odor ] Causes of Odor.

Preparation

- Check whether odor is actually in A/C evaporator by switching from fresh air to recirculation.

The odor can only be removed by cleaning with the (VAS 6189) if it originates in the evaporator.

- Check plenum chamber and water drain valves installed there and clean them if necessary. Refer to => [ Plenum Chamber Water Drain, Checking and Cleaning ] Service and Repair.

- Remove dust and pollen filter and check it for odor and contamination. Refer to=> [ Dust and Pollen Filter ] Service and Repair.

On this vehicle, the dust and pollen filter is installed between Fresh Air Blower (V2) and evaporator, therefore it must be removed for the cleaning.

- Clean the installation compartment for dust and pollen filter of heating and A/C unit of leaves, dust and other contaminants. Refer to => [ Dust and Pollen Filter ] Service and Repair.

- Reseal opening on A/C unit through which dust and pollen filter was removed.

- Start the engine.

- Adjust the Climatronic control module (J255) to "recirculation mode", and switch the A/C compressor off (the indicator lamp in the AC is off).

- Open instrument panel vents and set the lowest temperature possible on the Climatronic control module (J255) ("Cold" temperature setting).

- Close the windows and the sunroof.

- Set Climatronic control module to lowest fresh air blow level and select "Instrument panel vent" for air flow direction.

Cleaning

- Shake the bottle of (VAS 6189/1) and then fill the (VAS 6189). Be sure to read the Operating Instructions that come with the (VAS 6189).

- Place (VAS 6189) in passenger side footwell.

- Start (VAS 6189) (according to operating instructions) and route outlet hose belonging to it so vapor escaping via A/C unit recirculated air opening (in passenger footwell behind glove compartment) is drawn in by Fresh Air Blower (V2).

- Close vehicle doors.

The cleaning process takes about 15 to 20 minutes. It is complete when vapor no longer comes out of outlet hose.

Finishing steps

- Switch (VAS 6189) off.

- Open vehicle doors and air out vehicle at least 10 minutes.

- Remove (VAS 6189) from vehicle and clean it according to operating instructions.

- Switch off ignition.

- Install dust and pollen filter. Refer to => [ Dust and Pollen Filter ] Service and Repair.