Level Control Solenoid Valve: Service and Repair
Central Valve
Removing
• The central valves are attached to the impact member under the bumper cover in the rear and on the left side.
- Remove rear bumper cover.
Always wear safety goggles!
• The DRC lines must be extracted before disconnecting them from the central valve. Refer to => [ Dynamic Ride Control (DRC), Draining and Filling ] Procedures.
• Perform this step on both wiring harnesses on the central valve.
- Remove the union nuts - 7 - and - 8 - or - 11 - and - 12 -, depending on the central valve.
- Remove the screws - 13 - and the central valve.
Installing
- Install in reverse order of removal. Note the following:
Tightening specifications, refer to => [ Central Valves Overview ] Service and Repair
- Install the central valve and bracket.
- Install the bolts.
- Install the DRC line connections for the appropriate lines on the central valve.
• The new central valve is filled and the shut-off valves are closed.
• Only when a new central valve is installed: open the shut-off valve on the new central valve and secure them with a locking nut. Refer to => [ Central Valves Overview ] Service and Repair.
Fill the DRC system. Refer to => [ Dynamic Ride Control (DRC), Draining and Filling ] Procedures.