Relay Panel Under Instrument Panel, Left Side
Relay Panel Under Instrument Panel, Left Side
Special tools, testers and auxiliary items required
• Protective Cap For Cable Connector (VAS 6223/9) from Fiber Optic Plier Repair Set (VAS 6223)
Removal
- Remove the driver side footwell vent.
- Disconnect the electric wires - 1 and 2 - from the relay panel.
- Release the spring - 4 - and remove the relay panel - 6 - downward.
- Disconnect the connector - 5 - if applicable.
- Disconnect the fiber optic cable connector - 3 - and free it up.
- Seal open wiring harness fiber optic connector - 2 - with (VAS 6223/9) - item 1 -.
• Protective cap prevents contamination of or mechanical damage to end face of fiber optic cable which would impair signal transmission.
- Release the tab - arrow - and remove fuse panel D - 2 - from the relay panel - 1 - toward the rear.
- Open the clip and remove the auxiliary fuse panel - 2 -.
- Open the clips - arrows - and remove the relay - 1 - and the control modules from the relay panels.
- Release the retainers - arrows - and remove the relay panel - 2 - from the relay/fuse panel - 1 - to the rear.
• Check the exact connector assignment in the current wiring diagram.
Installation
• Tightening specification, refer to => [ Tightening Specification: Relay Panel Under Instrument Panel On Left Side With A Threaded Connection ] Instrument Panel Relay Carrier and Fuse Panel and A-Pillar Overview.
Install in reverse order of removal. Note the following:
- Install the driver side footwell vent.