Crankshaft Axial Play, Measuring
Crankshaft Axial Play, Measuring
Special tools, testers and auxiliary items required
• Dial Gauge Holder (VW 387)
• Dial Gauge 0-10 mm (VAS 6079)
Procedure
- Attach the (VAS 6079) together with the (VW 387) to the cylinder block and set indicator against crankshaft counterweight.
- Press the crankshaft against the dial gauge by hand and set the gauge to "0".
- Press the crankshaft off the dial gauge and read the measurement.
Axial clearance:
• New: 0.07 to 0.23 mm.
• Wear limit: 0.30 mm.