Thermostat Housing: Service and Repair
Connecting Piece with Coolant Thermostat
Special tools, testers and auxiliary items required
• Hose Clip Pliers (VAS 6362)
Removing
- Drain the coolant. Refer to => [ Cooling System, Draining and Filling ] Procedures.
- Remove the ribbed belt from the tensioning element. Refer to => [ Ribbed Belt ] Ribbed Belt.
- Remove the bolt - 1 - and disconnect the exhaust gas recirculation (EGR) coolant thermostat and connection from the connection.
• Ignore - 2 and 3 -.
- Remove the coolant hose; to do this, loosen the hose clamp - 1 -.
- Remove the bolts - arrows - and the coolant thermostat with the connection.
Installing
Install in reverse order of removal. Note the following:
• For the correct tightening specifications, refer to => [ Coolant Pump and Coolant Thermostat Overview ] Service and Repair.
• Replace O-rings.
• Secure all hose connections with the hose clamps appropriate for the model, refer to the Parts Catalog.
- Clean the sealing surface.
- Install the ribbed belt. Refer to => [ Ribbed Belt ] Ribbed Belt.
- Fill with coolant => [ Filling ] Procedures.