Battery
Battery
Pollution risk.
• Battery disposal regulations must be followed when disposing of batteries.
Removing
- Switch off ignition and remove ignition key.
- Remove the luggage compartment floor - 3 -.
- Remove the dirt tray, if applicable.
- Remove the bass box - 2 - if applicable.
- Fold back the carpet - 1 - over the flap.
- Remove the battery cover.
- Connect the battery charger for battery support mode.
- Remove the vehicle tools, if applicable, - 2 - and the bracket.
- Open the cover - 7 - over the battery negative "-" terminal.
- Loosen nut - 6 - a few turns and remove the battery ground (GND) cable clamp from battery terminal.
- Disconnect the central gas vent hose - 8 -.
- Remove the bolts - arrows - on the battery mounting bracket - 1 -.
- Remove the battery - 5 - slightly from the battery mount.
- Open the cover - 4 - over the battery positive terminal.
- Loosen the nut - 3 - several turns and remove the positive cable clamp with fuse panel A (SA) from the battery terminal.
- Remove battery from luggage compartment.
Installing
• Tightening specification, refer to => [ Battery Overview ] Battery Overview.
• Only maintenance-free batteries conforming to standards TL82506 (as of December 1997) and VW75073 (as of August 2001) may be installed.
• Batteries from the Audi Parts Program have a bottom strip-adapter for adapting to different grip channels. For information on how to use the base strip adapter, if applicable, see the battery operating instructions.
- Insert the battery in the battery mount so the base strip engages in the battery mount retaining strip - arrow -.
• It should no longer be possible to move the battery.
- Position battery bracket - 1 -.
• Lug at battery bracket must engage in recess at battery base strip.
- Tighten the battery bracket screws - arrows -.
- Connect central venting system hose - 8 - while observing notes.
With the ignition and electrical consumers switched off, connect the battery - 5 - in the following sequence:
- Connect positive cable terminal clamp - 3 - by hand to battery positive terminal "+" and tighten nut.
- Disconnect the connector - 3 - on the battery monitoring control module (J367) - 1 -.
- Connect the battery ground (GND) cable clamp by hand to battery negative "-" terminal and tighten the nut - 1 -.
- Connect the electrical connector on the battery monitoring control module (J367).
- Check battery after installation for secure seating.
- Install the battery cover..
- After replacing, adapt the battery in the Guided Fault Finding or Guided Functions mode using the Vehicle Diagnostic Tester
- Continue following the instructions on the vehicle diagnostic tester display in the case of a new battery.
When the battery is connected, the following steps must be performed:
• Activate the power window regulator one-touch up/down function.
• Check DTC memories of all control modules and erase the "undervoltage"DTC, if necessary, using the Vehicle Diagnostic Tester.
• After connecting the power supply, the ABS warning lamp may only go out after the vehicle has been driven a few yards.