Drive Belts, Mounts, Brackets and Accessories: Service and Repair
Accessory Assembly Bracket
Special tools, testers and auxiliary items required
• Locking Pin (T10060A)
Removing
- Disconnect the electrical connector on the mass airflow (MAF) sensor (G70) - 3 -.
- Open clips - 1 and 2 - and remove air guide hose from MAF sensor.
- Remove front air intake connector on lock carrier - 4 -.
- Remove engine cover.
- Pull the Evaporative Emission (EVAP) canister with connected lines upward - arrow - out of the retainer and lay it aside.
• Before removing the ribbed belt, mark the turning direction on it with chalk or a felt tip pen. A reversed turning direction can cause damage to the belt under operating conditions.
- Pivot the ribbed belt tensioner in direction of - arrow - to relieve tension on ribbed belt.
- Secure tensioning element using the (T10060A).
- Remove ribbed belt.
- Remove ribbed belt tensioner - arrows -.
- Discharge the refrigerant circuit.
- Remove the generator.
- Remove center noise insulation fasteners - 1 to 4 -.
- Remove the right noise insulation - arrows -.
- Remove noise insulation frame - arrow -.
- Remove the A/C compressor.
- Remove the accessory assembly bracket - bolts - 1 through 6 -.
Installing
Installation is performed in the reverse order of removal, noting the following.
• For the correct tightening specifications, refer to => [ Ribbed Belt and Assembly Bracket Overview ] Ribbed Belt and Assembly Bracket Overview.
- Tighten the bolts in the sequence - 1 through 6 -.
- Install the generator.
- Install A/C compressor.
- Install the ribbed belt. Refer to => [ Ribbed Belt ] Ribbed Belt.
- Connect the battery.