Selector Lever Position "P" Locking Lever
Selector Lever Position "P" Locking Lever
• Lubricate the bearings and the sliding surfaces with poly lubricant (G 052 142 A2).
Removing
- Remove the selector lever. Refer to => [ Selector Lever ] Selector Lever.
- Pry out both the left and right bushings - 2 - with a screwdriver.
- Remove the selector lever position "P" locking lever.
Installing
Install in reverse order, paying attention to the following:
- Insert the locking lever and secure it with both left and right bushings - 2 -.
- Check the emergency relase lever function.
• The emergency release lever - arrow - must move easily and can be moved up and down.
• If it is difficult to move the emergency release lever - arrow - the bushings are installed incorrectly.
• If the emergency release lever is difficult to move, the ignition key removal lock does not work.
- Install the selector lever. Refer to => [ Selector Lever ] Selector Lever.