Crankshaft, Measuring Axial Play
Crankshaft, Measuring Axial Play
Special tools, testers and auxiliary items required
• Dial Gauge Holder (VW 387)
• Dial Gauge 0-10 mm (VAS 6079)
Procedure
- Attach the (VAS 6079) together with (VW 387) to cylinder block and set indicator against crankshaft counterweight.
- Press crankshaft by hand against gauge and set gauge to "0".
- Press crankshaft off gauge and read value.
Axial clearance:
• New: 0.07 to 0.23 mm.
• Wear limit: 0.30 mm.