01VA Transmission
ATF Lines and Cooler, Cleaning
Special tools, testers and auxiliary items required
• Drip tray (VAG1306)
• Hose, approx. 18 mm
• Compressed air gun, standard
• Protective glasses
• Always blow compressed air through oil cooler and ATF lines (max. 10 mbar) before installing a replacement transmission.
• When installing ATF lines, insert into transmission or cooler by hand until impact first and then tighten bolts.
CAUTION!
Wear protective glasses.
- Place drip tray (VAG1306) underneath.
- Remove bolt - 2 -.
- Disconnect ATF lines from transmission.
- Slide a hose with approx. 18 mm diameter onto ATF line - A - and secure with hose clamp. Place the other end of the hose into an appropriate container.
- Blow through ATF line - B - with compressed air gun.
- Change hose from ATF line - A - to ATF line - B - and repeat procedure.
- Replace O-ring - 1 -.
- Coat O-ring with ATF.
- Insert ATF lines completely into transmission by hand until stop.
- Re-secure ATF lines.
- Then check ATF level and top off. Refer to => [ ATF Level, Checking ] .