FREE REPAIR MANUALS & LABOR GUIDES 1982-2013 Vehicles
Courtesy of Operation CHARM: Car repair manuals for everyone.

Basic Setting






Basic Setting

With engine stopped and ignition switched on, the following operation can be carried out with the "Function 04" basic setting:

Adaptation of the Throttle Drive Control to the Engine Control Module (ECM) => Display group 060. Refer to => [ Throttle Valve Control Module, Adapting ] Throttle Valve Control Module, Adapting.

Vehicles with automatic transmission: Adaptation of kick-down function of Throttle Position (TP) Sensor to Engine Control Module (ECM) => Display group 063. Refer to => [ Kick-Down Function, Adapting ] Testing and Inspection.

With the engine running, the following operations can be performed with the basic setting function:

Generation of readiness code. Refer to => [ Readiness Code, Generating ] Readiness Code, Generating.

Performance of Oxygen Sensor (O2S) and Oxygen Sensor control. Refer to => [ Oxygen Sensor and Sensor Control before Catalytic Converter, Checking ] Oxygen Sensor and Sensor Control Before Catalytic Converter, Checking.

Conditions for operations with engine running

No DTCs stored in Diagnostic Trouble Code (DTC) memory

Coolant temperature at least 80° C.

Electrical devices switched off (coolant fan must not run during the test).

Air conditioning switched off.

Vehicles with automatic transmission: Selector lever in position P or N.

Work sequence

- Connect tester (VAS 5051) and select vehicle system "01 - Engine electronics". Refer to => [ VAS5051, Connecting and Selecting Functions ] VAS 5051, Connecting and Selecting Functions. Ignition must be switched on for this.

or, depending on desired operation:

- Start engine.

Display on (VAS 5051):





- In selection - 1 -, click on diagnostic function " 04 - Basic Setting".

Display on (VAS 5051):





1 - Enter display group

- Enter desired 3-digit display group number in button field - 2 - and press Q button to confirm input.

Example:

- Press buttons 0, 0 and 1 to select "display group number 001" and press Q button to confirm input.

Display on (VAS 5051):





1 - Measured values not in basic setting

2 - Measured values in basic setting

3 - Display group X

A - Activating basic setting

Basic setting is initiated after button A is pressed.

Display on (VAS 5051):





1 - Display field 1

2 - Display field 2

3 - Display field 3

4 - Display field 4

- End function "04 - Basic setting" by pressing arrow button.