53, Graphics Channel 2 (Active Electrical Outputs)
- When an A/C system electrical output is activated, segments of the "88.8" display identified by alphanumeric code, will be illuminated.- The decimal point in the "88.8" display is not illuminated when using this channel.
88.8 Display:
a1 - Fan for interior temp. sensor
b1 - Fresh air/recirculation flap closed (recirculation mode)
c1 - Heater valve closed
d1 - Bi-directional wiring harness
e1 - A/C compressor on
f1 - Coolant fan first speed on
g1 - System function OK, See Note.
a2 -
b2 - Air flow flap open
c2 - Air flow flap closed
d2 -
e2 - Footwell/defroster flap in "footwell" position
f2 - Footwell/defroster flap in "defrost" position
g2 - System function OK, See Note.
a3 -
b3 - Center flap in "instrument panel outlet" position
c3 - Center flap in "footwell outlet/defrost" position
d3 -
e3 - Temperature flap in "cold air" position
f3 - Temperature flap in warm air position
g3 - System function OK, See Note.
NOTE:*Segments -g1-, -g2- and -g3- must be illuminated simultaneously to indicate system function is OK.